Studio-technologies 58 2000 Instrukcja Użytkownika Strona 58

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 61
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 57
Model 58/59 User Guide Issue 4, December 2000
Studio Technologies, Inc. Page 59
for Surround
Signal Signal
Connections High (+) Low (–) Shield
MONITOR OUT A 24 12 25
NOT USED 10 23 11
MONITOR OUT B 21 9 22
NOT USED 7 20 8
METER OUT 18 6 (See Note 3) 19
NOT USED 4 17 5
BYPASS IN 15 3 16
NOT USED 1 14 2
Notes: 1) Connector type on Model 58 is 25-pin D-subminiature
female. Installer must provide plug (male). Connector
uses 4-40 threaded inserts for locking with mating plug.
2) Wiring scheme loosely follows Tascam DA-88
convention. Modified DA-88-type wiring harnesses are
required, along with 4-40 screw threads.
3) Meter output is unbalanced. Pin 6 is internally
connected to Model 58 shield.
Figure 13. Single-Channel Mode Connections
for Monitor Outputs, Meter Output, and Bypass
Input
Signal Signal
Connections High (+) Low (–) Shield
SEND 1 24 12 25
RETURN 1 10 23 11
NOT USED 21 9 22
NOT USED 7 20 8
SEND 2 18 6 19
RETURN 2 4 17 5
NOT USED 15 3 16
NOT USED 1 14 2
Notes: 1) Connector type on Model 58 is 25-pin D-subminiature
female. Installer must provide plug (male). Connector
uses 4-40 threaded inserts for locking with mating plug.
2) Wiring scheme loosely follows Tascam DA-88
convention. Modified DA-88-type wiring harnesses are
required, along with 4-40 screw threads.
Figure 14. Single-Channel Mode Connections
for Inserts
Przeglądanie stron 57
1 2 ... 53 54 55 56 57 58 59 60 61

Komentarze do niniejszej Instrukcji

Brak uwag